Key Features for Your Success:

Extensive Question Bank: Engage with over 2,500 practice questions covering every section of the NEC Master Exam, fostering a deep understanding of the code.

In-Depth Explanations: Gain clarity with thorough explanations for each question, ensuring you comprehend the reasoning behind every answer.

Progress Analytics: Monitor your performance in real-time to identify strengths and target areas that need improvement.

Custom Test Creation: Bookmark challenging questions and create personalized practice tests using your collected questions, tailored to your specific needs.

Up-to-Date Content: Incorporates the latest 2023 NEC standards and updates, ensuring you study the most current and accurate material.

Download NEC Master Exam Prep today and take the next step towards becoming a master electrician!

Example questions

Let's look at some sample questions

What is the role of a partition, fence, or screen when installing equipment in rooms with high and low voltage?

To enhance the room's aesthetic appeal.To separate the high-voltage equipment from low-voltage equipment safely.To support the equipment structure.To serve as additional grounding for the equipment.
A partition, fence, or screen effectively separates high-voltage equipment from the space occupied by low-voltage equipment to improve safety.

What is the minimum load for each outlet for general-use receptacles not used for general illumination in all occupancies?

Based on nominal branch-circuit voltagesFixed at 100 volt-amperes per outlet1000 volt-amperes per outletNot less than 120 volt-amperes per outlet
According to Article 220.14, the minimum load for each outlet for general-use receptacles should be based on nominal branch-circuit voltages.

What specific information must an interrupter switch nameplate include?

Circuit type and color of conductorsManufacturer's name and locationType or designation, current rating, fault closing ratingRecommended installation date
The nameplate of an interrupter switch must include the manufacturer's type or designation, continuous current rating, interrupting current rating, fault closing rating, and maximum voltage rating.

In what circumstance is a supplemental electrode not required if a single rod, pipe, or plate electrode is used?

If the electrode is longer than 8 feetIf the electrode is driven at a 45-degree angleIf the electrode has a resistance to earth of 25 ohms or lessIf the electrode is galvanized
A supplemental electrode is not required if a single rod, pipe, or plate electrode has a resistance to earth of 25 ohms or less.

Under which article do the bending requirements for nonmetallic underground conduits fall?

Article 354.24Article 300.5Article 355.12Article 250.142
The bending requirements for nonmetallic underground conduits are specified in Article 354.24.

What minimum wire-bending space is required for noninsulated busbars?

100 mm150 mm200 mm250 mm
A minimum wire-bending space of 250 mm (10 inches) is required for noninsulated busbars.

Which type of optical fiber cable is installed in Class I, Division 1 hazardous locations and sealed according to specific regulations?

Type OFNPType OFCRType OFCGType OFN
Optical fiber cable Type OFNP must be installed and sealed in accordance with 501.15 for use in Class I, Division 1 locations.

What is the radius classification for booths where flammable gases or vapors are released while extracting plant oil?

Class II, Division 1 or Zone 1Class III onlyZone 2 or Class I, Division 3Class I, Division 1 and Zone 1
Booths where flammable gases or vapors are released in the process of extracting plant oil are classified as Class I, Division 1 and Zone 1 areas.

What protection method is allowed for cables accessible to the public at carnivals according to Article 525?

Buried undergroundCovered with conductive mattingGuarded by nonconductive matting secured to the surfaceLeft exposed if supervised
Flexible cords or cables should be covered with nonconductive matting secured to the surface to minimize tripping hazards.

What describes the role of the Microgrid Control System (MCS)?

Limits energy storage capacityCoordinates interaction among various power sourcesSolely manages the disconnection from primary sourcesRegulates temperature within the microgrid
The Microgrid Control System (MCS) coordinates interaction between multiple power sources of varying types, manufacturers, and technologies.